[yaml] Configuration_InjectionCouplingTool
Viewer
*** This page was generated with the meta tag "noindex, nofollow". This happened because you selected this option before saving or the system detected it as spam. This means that this page will never get into the search engines and the search bot will not crawl it. There is nothing to worry about, you can still share it with anyone.
- -
- col1: 'Process (only 1 case should be set to 1, TBC)'
- col2: '0'
- col3: '0'
- col4: '0'
- col5: '1'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Unique Identifier'
- col2: LP1
- col3: LP2
- col4: LP3
- col5: LP4
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: Geometry
- col2: ""
- col3: ""
- col4: ""
- col5: ""
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Chamber diameter [mm]'
- col2: '50'
- col3: '50'
- col4: '50'
- col5: '50'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Chamber length [mm]'
- col2: '344'
- col3: '344'
- col4: '362'
- col5: '362'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'LOX throttle length [mm]'
- col2: '4'
- col3: '4'
- col4: '4'
- col5: '4'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'LOX throttle diameter [mm]'
- col2: '2.2'
- col3: '2.2'
- col4: '2.2'
- col5: '2.2'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'LOX post length [mm]'
- col2: '111'
- col3: '111'
- col4: '127'
- col5: '127'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'LOX post diameter [mm]'
- col2: '5.5'
- col3: '5.5'
- col4: '5.5'
- col5: '5.5'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Load Point Definition'
- col2: ""
- col3: ""
- col4: ""
- col5: ""
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Fuel (CH4/H2)'
- col2: H2
- col3: H2
- col4: H2
- col5: H2
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Chamber pressure [bar]'
- col2: '60'
- col3: '55'
- col4: '65'
- col5: '69'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Chamber ROF [-]'
- col2: '1.26'
- col3: '1.58'
- col4: '1.16'
- col5: '1.2'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'LOX massflux [kg/s]'
- col2: '0.319'
- col3: '0.318'
- col4: '0.327'
- col5: '0.348'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Fuel massflux [kg/s]'
- col2: '0.103'
- col3: '0.051'
- col4: '0.082'
- col5: '0.06'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'LOX dome pressure [bar]'
- col2: '90'
- col3: '86'
- col4: '94'
- col5: '102'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Fuel dome pressure [bar]'
- col2: '137'
- col3: '78'
- col4: '107'
- col5: '92'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'LOX injection temperature [K]'
- col2: '111'
- col3: '111'
- col4: '112'
- col5: '112'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Fuel injection temperature [K]'
- col2: '161'
- col3: '162'
- col4: '168'
- col5: '170'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Combustion efficiency [-]'
- col2: '0.93'
- col3: '0.93'
- col4: '0.99'
- col5: '0.99'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Contraction ratio [-]'
- col2: '8.753194916'
- col3: '8.753194916'
- col4: '8.753194916'
- col5: '8.753194916'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: Other
- col2: ""
- col3: ""
- col4: ""
- col5: ""
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: OutputPath
- col2: 'D:\_BKC\TestDataAnalysis\'
- col3: 'D:\_BKC\TestDataAnalysis\'
- col4: 'D:\_BKC\TestDataAnalysis\'
- col5: 'D:\_BKC\TestDataAnalysis\'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'FilePath to axiaial sound speed distribution'
- col2: 'D:\RASoft\P8analysis\StabilityPredictionTool\Data\AxialDistributionSpeedOfSound_H2_ESA_TDE_BreadExp.csv'
- col3: 'D:\RASoft\P8analysis\StabilityPredictionTool\Data\AxialDistributionSpeedOfSound_H2_ESA_TDE_BreadExp.csv'
- col4: 'D:\RASoft\P8analysis\StabilityPredictionTool\Data\AxialDistributionSpeedOfSound_H2_ESA_TDE_BreadExp.csv'
- col5: 'D:\RASoft\P8analysis\StabilityPredictionTool\Data\AxialDistributionSpeedOfSound_H2_ESA_TDE_BreadExp.csv'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Maximum number of mode to be investigated [-]'
- col2: '10'
- col3: '10'
- col4: '10'
- col5: '10'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Maximum frequency to be investigated [Hz]'
- col2: '25000'
- col3: '25000'
- col4: '25000'
- col5: '25000'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Flame definition'
- col2: ""
- col3: ""
- col4: ""
- col5: ""
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Effective length of sound speed distribution for tangetnial modes [-]'
- col2: '0.25'
- col3: '0.25'
- col4: '0.25'
- col5: '0.25'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Effective length of sound speed distribution for longitudinal modes [-]'
- col2: '1'
- col3: '1'
- col4: '1'
- col5: '1'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Distance to flaceplate of lifted flame [mm]'
- col2: '0'
- col3: '0'
- col4: '0'
- col5: '0'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Number of injectors'
- col2: '1'
- col3: '1'
- col4: '1'
- col5: '1'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
- -
- col1: 'Reference temperature of sound speec profile'
- col2: '140'
- col3: '140'
- col4: '140'
- col5: '140'
- col6: ""
- col7: ""
- col8: ""
- col9: ""
- col10: ""
Editor
You can edit this paste and save as new:
File Description
- Configuration_InjectionCouplingTool
- Paste Code
- 24 Jun-2021
- 6.14 Kb
You can Share it: